Newborn Phototherapy Lamp
For use in newborn phototherapy devices
160 degree beam angle
No need to use a transformer or starter for installation
Replaceable with a 20-watt fluorescent lamp with greater therapeutic effectiveness
Aluminum body with clear acrylic coating
One-year replacement warranty
Has a serial number with lamp traceability
LED lamp is more cost-effective than fluorescent lamps due to its longer lifespan (at least ten times)
160 degree beam angle
No need to use a transformer or starter for installation
Replaceable with a 20-watt fluorescent lamp with greater therapeutic effectiveness
Aluminum body with clear acrylic coating
One-year replacement warranty
Has a serial number with lamp traceability
LED lamp is more cost-effective than fluorescent lamps due to its longer lifespan (at least ten times)
Orange Collared Gowns
They are made out of superior material. These are not the same as your usual Gowns which are made out of Spunbond material.
This Mid Risk Gown cnosists of Arms which are made out of Spunlace SMS and PE film on the outside.
The whol front of the Gown consists of SSMMS high absorbent material from the outside and with PE film on the inside, this is from the Shoulders to the bottom of the Gown.
Portable Infant Incubator
Capable of adjusting the chamber temperature (Air) from 28 to 37 degrees Celsius with an accuracy of 0.1 degrees Celsius and a corresponding indicator
Capable of adjusting the infant's body temperature (Skin) from 28 to 37 degrees Celsius with an accuracy of 0.1 degrees Celsius and a corresponding indicator
With a temperature sensor inside the chamber and a corresponding indicator (Air Sensor)
With an infant's body temperature sensor and a corresponding indicator (Skin Sensor)
With an oxygen input terminal for oxygenating the infant
With a 12-volt battery and a battery charge status indicator
With the ability to maintain the set temperature using the battery for 120 minutes
With a 5-liter oxygen capsule
With an oxygen manometer and flowmeter
With a folding wheeled trolley for transport by ambulance or helicopter
With a special wire for connecting to the ambulance lighter
With an ABS infant tray
With a special infant mattress with washable and disinfectable leather cover
With a disposable and easy-to-replace air filter
With a plexiglass chamber Transparent
With access hatches for the infant and the passage of the required equipment, on the chamber
With four silent wheels for easy transportation, two of which are lockable
Audible and visual warning of a defect in the temperature sensor system inside the chamber (Air Sensor Failure)
Audible and visual warning of a defect in the infant's body temperature sensor system (Skin Sensor Failure)
Audible and visual warning of a temperature increase of more than 39.3 degrees Celsius (Over Heat)
Audible and visual warning of air circulation interruption (Fan Failure)
Audible and visual warning of battery depletion (Low Battery)
Audible and visual warning when the power supply is disconnected (Power Failure)
The sound level inside the chamber is less than 48 decibels
The time for the chamber temperature to reach the temperature set by the nurse is a maximum of 25 minutes (at an ambient temperature of 25 degrees Celsius)
Device dimensions: length 88 cm, width 46 cm, height maximum 107 cm and Minimum 73 cm
Mattress dimensions: 25 x 60 cm
Weight: 30 kg
Availability of serum base and phototherapy
Pulse oximeter nemoxy 412
Pulse oximeter nemoxy 412: has memory to store 24-hour patient status history, has LCD and battery capacity display-6-hour battery charging
Download Catalog
Pulse oximeter nemoxy 512
Pulse oximeter nemoxy 512: A portable monitor used to measure the prolonged and non-invasive percentage of saturated oxygen in the arterial blood (spo2%).
Download catalog
Recovery Cot of Newborns
Can be used under phototherapy and baby warmer
With a cabinet for baby items
With a transparent plexiglass basin, resistant to washing and disinfection
With an ABS shock absorber on the base of the device
With a place to place baby items on the ABS carrying handle
With a special baby mattress with a washable and disinfectable leather cover
With an electrostatic powder paint
With the ability to adjust the baby's pelvis angle in three desired positions
Length 52 cm, width 102 cm, height 90 cm
Mattress dimensions: 70 x 40 cm
Weight: 15 kg
Red Collared Gowns
They are made out of Superior material. Please note these are not the same as your usual Gowns which are made out of Spunbond material.
This High Risk Gown consists of Full front and Arms which are made out of Spunlace SSMMS which have an absorbent material on the outside with PE film in middle and abosbent layer on the inside.
Safira vital signs monitor
Safira vital signs monitor: Storage capability 1024 measured pressure and has audio and visual alarms defining or removing alarms for each module
Download Catalog
Saipo dermic burner head
SG-100 injection pump
The SG - 100 syringe injection pump was calibrated with bolus, anti-bolus, automatic detection of the size and brand of the syringe, as well as the possibility of any type of syringe
Download Catalog
The central system of Saba
Vectra vital signs monitor
Vectra vital signs monitor suitable for infants, children and adults with the ability to operate with City electricity or batteries, with the ability to operate with City electricity or batteries
Download Catalog