Showing 13–24 of 37 results

Infant Incubator

$1 211.38
With the ability to adjust the temperature of the chamber (Air) from 28 to 37 degrees Celsius and in special mode up to 39 degrees Celsius with an accuracy of 0.1 degrees Celsius and a corresponding indicator It has the ability to adjust the temperature of the infant's body (Skin) from 28 to 37 degrees Celsius and in special mode up to 39 degrees Celsius with an accuracy of 0.1 degrees Celsius and a corresponding indicator It has a temperature sensor inside the chamber and a corresponding indicator (Air Sensor) It has infant's body temperature sensor and a corresponding indicator (Skin Sensor) It has the ability to adjust the humidity inside the chamber from 25 to 90 percent relative humidity and a corresponding indicator It has an oxygen inlet terminal for oxygenating the infant It has a high-efficiency fan for circulating air inside the chamber with minimal noise It has an ABS infant tray It has the ability to change the angle of the infant tray from both sides of the tray It has a special infant mattress with a washable and disinfectable leather cover It has a disposable and easy-to-replace air filter It has two cabinets for placing infant accessories It has a serum stand and a monitor or CPAP stand It has transparent plexiglass enclosure With access hatches for the infant and the passage of the required equipment on the enclosure With four silent wheels, two of which are lockable Audible and visual alarm for temperature increase above 38°C or in special mode above 39.6°C Audible and visual alarm for failure in the temperature sensing system inside the enclosure (Air Sensor Failure) Audible and visual alarm for failure in the infant's body temperature sensing system (Skin Sensor Failure) Audible and visual alarm for thermostat for temperature increase above 38°C or in special mode above 40°C (Cut Out) Audible and visual alarm for temperature deviation inside the enclosure (A.S.D) Audible and visual alarm for fan failure (Fan Failure) Audible and visual alarm for power supply failure (Power Failure) Audible and visual alarm for empty water tank (Low Water) Visual warning of low battery (Low Battery) Electrical supply 240-220 volts 50 Hz 1.2 amps Sound level inside the chamber less than 48 dB Time for the chamber temperature to reach the temperature set by the nurse, maximum 25 minutes (at an ambient temperature of 25 degrees Celsius)

Infant Oxygen Hood

$31.31
Special for children
With a transparent Plexiglas body
Can be used in incubators and resuscitation beds, phototherapy and neonatal surgery
With oxygen nozzle inlet
Can adjust the degree of oxygen inlet and outlet
Capacity 12 liters
Length 24 cm, width 27.5 cm, height 21.5 cm
Opening 11 x 14.5 cm

Infant Warmer

$206.65
It has the ability to automatically control the temperature according to the infant's body temperature with an accuracy of 0.1 degrees Celsius. It has the ability to control the temperature without considering the skin sensor (Manual). It has the ability to create local heat on the infant's body from 28 to 37 degrees Celsius. It has a infant's body temperature sensor (Skin Sensor). It has two functions: Auto and Manual. It has a light for sufficient light during examinations. It can be adjusted by the nurse. It has a ceramic heater with a special protector. It has three wheels for easy transportation. It is possible to adjust the height of the device head. Audible and visual alarm when the temperature rises above 39.3 degrees (Over Heat) Audible and visual alarm when the temperature sensor fails (Skin Sensor Failure) Audible and visual alarm when the temperature deviates (A.S.D) Audible alarm when the device is powered off (Power Failure) Visual alarm when the battery is low (Low Battery) Length 67 cm, width 64 cm, maximum height 175 cm Weight: 14 kg

Lowerlake medical disposable syringe

Blood transfusions in infants Pericardiosynthesis Liposuction in limited volume Preparing adipose tissue for fast Transfer Preparing a fat sample for Stem Cell Separation Ultrasound-controlled breast cysts are drained. Amniocentesis Preparation of a sample for cytology of the thyroid and lymph nodes (FNA) Removing the clot from the vessels, like the coronary arteries. Pulling joint fluid Pulling pus and fluids from various cysts and body lesions Pulling blood and fluids from the chest and abdominal cavity. Taking a sample of femoral vein blood

Lowerlake medical disposable syringe

Suitable for blood transfusions and use in the operating room It has a special coating to reduce pain during injections. Clear barrel with clear grading It has a medical stainless steel burner. Sterilized with ethylene oxide gas without microbial complications. wessemite Planger's psychic move in barrel Needle head size : 236 - 22 - 21 Three-piece gasket. The capacity of the syringe Carton is 3 mL: 550 PCs , 1800 PCs The capacity of the syringe Carton is 5 ml 450 1500 The capacity of the syringe Carton is 10 ml : 360 PCs, 1280 PCs Expiry date: 3 years after production

Lowerslip medical disposable syringe

Suitable for injections and blood transfusions produced with raw materials and medical grade PP It has a special coating to reduce pain during injections. Clear barrel with clear grading It has a medical stainless steel burner. Sterilized with ethylene oxide gas without microbial complications and toxicity. Planger's psychic move in barrel Needle head size: 236-22-21 Three-piece gasket. The capacity of the syringe Carton is 3 mL : 550 PCs , 1800 PCs The capacity of the syringe Carton is 5 ml 450 1500 The capacity of the syringe Carton is 10 ml 360 digits 1280 digits Expiry date: 3 years after production

Medium Neonatal Oxygen Hood

$28.47
For newborns and children Has a transparent body made of Plexiglas Can be used in incubators, resuscitation beds, phototherapy, and neonatal beds Has an oxygen nozzle inlet Can adjust the oxygen inlet and outlet levels Capacity 9 liters Length 22 cm, width 23.5 cm, height 17 cm Opening 12 x 13 cm

Neonatal Oxygen Hood

$27.04
For newborns With transparent Plexiglas body Can be used in incubators, resuscitation beds, phototherapy, and newborn beds With oxygen nozzle inlet Can adjust the oxygen inlet and outlet degree Capacity 6.5 liters Length 20.5 cm, width 22 cm, height 14.5 cm Opening: 9.5 x 12.5 cm, angled

Neonatal Phototherapy

$178.75
دارای نمایشگر LCDدیجیتال With timer to display lamp life With phototherapy timer with reset capability Available with 4 LED lamps for phototherapy Able to change the angle of the device head to change the direction of light radiation Able to be used on incubators, neonatal beds and neonatal resuscitation beds Able to adjust the height to the appropriate level Able to easily access the lamps for replacement A warning of the end of the lamp life Warning of lamp life expiration 14-watt LED lamp with blue light with a wavelength of 450 nm for phototherapy, with a traceable serial number and a useful life of 30,000 hours, aluminum body with transparent acrylic coating طول 64 سانتی متر، عرض 76 سانتی‌متر،حداکثر ارتفاع 165سانتی‌متر Lamp dimensions: length 60 cm, diameter 3 cm Weight: 20 kg

Neonatal Recovery Cot

$356.29
It has the ability to automatically control the temperature according to the baby's body temperature with an accuracy of 0.1 degrees Celsius. With the ability to control the temperature without considering the skin sensor (Manual). With the ability to create local heat on the baby's body from 28 to 37 degrees Celsius. With a baby's body temperature sensor (Skin Sensor). With two functions: Auto and Manual. With a light for sufficient light during examinations. With a ceramic heater with special protection With four silent wheels for easy transportation, two of which are lockable With the ability to adjust the height of the device's head With a baby bed integrated with the device With a special baby mattress with washable and disinfectable leather cover With the side walls of the baby bed made of transparent polyglass with the ability to open and close With a graduated side wall of the baby bed to measure the baby's height Audible and visual warning when the temperature increases more than 39.3 degrees (Over Heat) Audible and visual warning when the temperature sensor fails (Skin Sensor Failure) Audible and visual warning when the temperature deviates (A.S.D) Audible warning when the device's power is cut off (Air Sensor Failure) A nurse's warning to visit the baby in manual mode (if the temperature sensor is cut off) Length 80 cm, width 44 cm, maximum height 187 cm Mattress dimensions: 36 x 66 cm Weight: 30 kg

Neonatal Resuscitation Table

$1 710.19
With a baby's body temperature sensor (Skin Sensor) With the ability to automatically control the temperature according to the baby's body temperature with an accuracy of 0.1 degrees Celsius With the ability to create local heat on the baby's body from 28 to 37 degrees Celsius With a set temperature display With a baby's body temperature display With a heat generation system power display from 10% to 100% With a ceramic heater with special protection With a suction system integrated with the device With a baby's health assessment timer (Apgar Timer) With an oxygen output adjustment system With the ability to manually change the angle of the bed up to 12 degrees forward With the ability to change the height of the baby's bed electrically With a light for sufficient light during examinations With a sliding tray for placing the radiology cassette With the ability to rotate the heater chamber (device head) to the sides, during radiology With a serum base With a monitor base or CPAP base With a tray for placing baby accessories With side walls of the baby's bed made of Transparent polyglass with the ability to open and close With a graduated side wall of the baby bed to measure the baby's height With an oxygen bottle holder With a special baby mattress with washable and disinfectable leather cover With four silent wheels for easy transportation, two of which are lockable Audible and visual alarm when the temperature rises above 39.3 degrees (Over Heat) Audible and visual alarm when the temperature sensor fails (Sensor Failure) Audible and visual alarm when the temperature deviates (A.S.D) Audible alarm when the device is powered off (Power. Failure) Visual warning of low battery (Low Battery) Audible and visual warning to remind the nurse to visit the baby after fifteen minutes in manual mode (if the temperature sensor is disconnected) Electrical supply 240-220 volts 50 Hz 2.7 amps Length 100 cm, width 65 cm, height 185 cm Adjustable bed height from 77 to 91 cm Adjustable bed inclination from 0 to 12 degrees Mattress dimensions: length 76, width 60 cm Device weight: 80 kg

Newborn Blindfold

$0.20
For use during phototherapy Possibility of reducing complications related to bilirubin reduction and preventing damage to the cornea Compatible with the size of the newborn's head in standard size