Infant Incubator
With the ability to adjust the temperature of the chamber (Air) from 28 to 37 degrees Celsius and in special mode up to 39 degrees Celsius with an accuracy of 0.1 degrees Celsius and a corresponding indicator
It has the ability to adjust the temperature of the infant's body (Skin) from 28 to 37 degrees Celsius and in special mode up to 39 degrees Celsius with an accuracy of 0.1 degrees Celsius and a corresponding indicator
It has a temperature sensor inside the chamber and a corresponding indicator (Air Sensor)
It has infant's body temperature sensor and a corresponding indicator (Skin Sensor)
It has the ability to adjust the humidity inside the chamber from 25 to 90 percent relative humidity and a corresponding indicator
It has an oxygen inlet terminal for oxygenating the infant
It has a high-efficiency fan for circulating air inside the chamber with minimal noise
It has an ABS infant tray
It has the ability to change the angle of the infant tray from both sides of the tray
It has a special infant mattress with a washable and disinfectable leather cover
It has a disposable and easy-to-replace air filter
It has two cabinets for placing infant accessories
It has a serum stand and a monitor or CPAP stand
It has transparent plexiglass enclosure
With access hatches for the infant and the passage of the required equipment on the enclosure
With four silent wheels, two of which are lockable
Audible and visual alarm for temperature increase above 38°C or in special mode above 39.6°C
Audible and visual alarm for failure in the temperature sensing system inside the enclosure (Air Sensor Failure)
Audible and visual alarm for failure in the infant's body temperature sensing system (Skin Sensor Failure)
Audible and visual alarm for thermostat for temperature increase above 38°C or in special mode above 40°C (Cut Out)
Audible and visual alarm for temperature deviation inside the enclosure (A.S.D)
Audible and visual alarm for fan failure (Fan Failure)
Audible and visual alarm for power supply failure (Power Failure)
Audible and visual alarm for empty water tank (Low Water)
Visual warning of low battery (Low Battery)
Electrical supply 240-220 volts 50 Hz 1.2 amps
Sound level inside the chamber less than 48 dB
Time for the chamber temperature to reach the temperature set by the nurse, maximum 25 minutes (at an ambient temperature of 25 degrees Celsius)
Infant Oxygen Hood
Infant Warmer
It has the ability to automatically control the temperature according to the infant's body temperature with an accuracy of 0.1 degrees Celsius.
It has the ability to control the temperature without considering the skin sensor (Manual).
It has the ability to create local heat on the infant's body from 28 to 37 degrees Celsius.
It has a infant's body temperature sensor (Skin Sensor).
It has two functions: Auto and Manual.
It has a light for sufficient light during examinations.
It can be adjusted by the nurse.
It has a ceramic heater with a special protector.
It has three wheels for easy transportation.
It is possible to adjust the height of the device head.
Audible and visual alarm when the temperature rises above 39.3 degrees (Over Heat)
Audible and visual alarm when the temperature sensor fails (Skin Sensor Failure)
Audible and visual alarm when the temperature deviates (A.S.D)
Audible alarm when the device is powered off (Power Failure)
Visual alarm when the battery is low (Low Battery)
Length 67 cm, width 64 cm, maximum height 175 cm
Weight: 14 kg
Lowerlake medical disposable syringe
Blood transfusions in infants
Pericardiosynthesis
Liposuction in limited volume
Preparing adipose tissue for fast Transfer
Preparing a fat sample for Stem Cell Separation
Ultrasound-controlled breast cysts are drained.
Amniocentesis
Preparation of a sample for cytology of the thyroid and lymph nodes (FNA)
Removing the clot from the vessels, like the coronary arteries.
Pulling joint fluid
Pulling pus and fluids from various cysts and body lesions
Pulling blood and fluids from the chest and abdominal cavity.
Taking a sample of femoral vein blood
Lowerlake medical disposable syringe
Suitable for blood transfusions and use in the operating room
It has a special coating to reduce pain during injections.
Clear barrel with clear grading
It has a medical stainless steel burner.
Sterilized with ethylene oxide gas without microbial complications. wessemite
Planger's psychic move in barrel
Needle head size : 236 - 22 - 21
Three-piece gasket.
The capacity of the syringe Carton is 3 mL: 550 PCs , 1800 PCs
The capacity of the syringe Carton is 5 ml 450 1500
The capacity of the syringe Carton is 10 ml : 360 PCs, 1280 PCs
Expiry date: 3 years after production
Lowerslip medical disposable syringe
Suitable for injections and blood transfusions produced with raw materials and medical grade PP
It has a special coating to reduce pain during injections.
Clear barrel with clear grading
It has a medical stainless steel burner.
Sterilized with ethylene oxide gas without microbial complications and toxicity.
Planger's psychic move in barrel
Needle head size: 236-22-21
Three-piece gasket.
The capacity of the syringe Carton is 3 mL : 550 PCs , 1800 PCs
The capacity of the syringe Carton is 5 ml 450 1500
The capacity of the syringe Carton is 10 ml 360 digits 1280 digits
Expiry date: 3 years after production
Medium Neonatal Oxygen Hood
Neonatal Oxygen Hood
Neonatal Phototherapy
دارای نمایشگر LCDدیجیتال
With timer to display lamp life
With phototherapy timer with reset capability
Available with 4 LED lamps for phototherapy
Able to change the angle of the device head to change the direction of light radiation
Able to be used on incubators, neonatal beds and neonatal resuscitation beds
Able to adjust the height to the appropriate level
Able to easily access the lamps for replacement
A warning of the end of the lamp life
Warning of lamp life expiration
14-watt LED lamp with blue light with a wavelength of 450 nm for phototherapy, with a traceable serial number and a useful life of 30,000 hours, aluminum body with transparent acrylic coating
طول 64 سانتی متر، عرض 76 سانتیمتر،حداکثر ارتفاع 165سانتیمتر
Lamp dimensions: length 60 cm, diameter 3 cm
Weight: 20 kg
Neonatal Recovery Cot
It has the ability to automatically control the temperature according to the baby's body temperature with an accuracy of 0.1 degrees Celsius.
With the ability to control the temperature without considering the skin sensor (Manual).
With the ability to create local heat on the baby's body from 28 to 37 degrees Celsius.
With a baby's body temperature sensor (Skin Sensor).
With two functions: Auto and Manual.
With a light for sufficient light during examinations.
With a ceramic heater with special protection
With four silent wheels for easy transportation, two of which are lockable
With the ability to adjust the height of the device's head
With a baby bed integrated with the device
With a special baby mattress with washable and disinfectable leather cover
With the side walls of the baby bed made of transparent polyglass with the ability to open and close
With a graduated side wall of the baby bed to measure the baby's height
Audible and visual warning when the temperature increases more than 39.3 degrees (Over Heat)
Audible and visual warning when the temperature sensor fails (Skin Sensor Failure)
Audible and visual warning when the temperature deviates (A.S.D)
Audible warning when the device's power is cut off (Air Sensor Failure)
A nurse's warning to visit the baby in manual mode (if the temperature sensor is cut off)
Length 80 cm, width 44 cm, maximum height 187 cm
Mattress dimensions: 36 x 66 cm
Weight: 30 kg
Neonatal Resuscitation Table
With a baby's body temperature sensor (Skin Sensor)
With the ability to automatically control the temperature according to the baby's body temperature with an accuracy of 0.1 degrees Celsius
With the ability to create local heat on the baby's body from 28 to 37 degrees Celsius
With a set temperature display
With a baby's body temperature display
With a heat generation system power display from 10% to 100%
With a ceramic heater with special protection
With a suction system integrated with the device
With a baby's health assessment timer (Apgar Timer)
With an oxygen output adjustment system
With the ability to manually change the angle of the bed up to 12 degrees forward
With the ability to change the height of the baby's bed electrically
With a light for sufficient light during examinations
With a sliding tray for placing the radiology cassette
With the ability to rotate the heater chamber (device head) to the sides, during radiology
With a serum base
With a monitor base or CPAP base
With a tray for placing baby accessories
With side walls of the baby's bed made of Transparent polyglass with the ability to open and close
With a graduated side wall of the baby bed to measure the baby's height
With an oxygen bottle holder
With a special baby mattress with washable and disinfectable leather cover
With four silent wheels for easy transportation, two of which are lockable
Audible and visual alarm when the temperature rises above 39.3 degrees (Over Heat)
Audible and visual alarm when the temperature sensor fails (Sensor Failure)
Audible and visual alarm when the temperature deviates (A.S.D)
Audible alarm when the device is powered off (Power. Failure)
Visual warning of low battery (Low Battery)
Audible and visual warning to remind the nurse to visit the baby after fifteen minutes in manual mode (if the temperature sensor is disconnected)
Electrical supply 240-220 volts 50 Hz 2.7 amps
Length 100 cm, width 65 cm, height 185 cm
Adjustable bed height from 77 to 91 cm
Adjustable bed inclination from 0 to 12 degrees
Mattress dimensions: length 76, width 60 cm
Device weight: 80 kg